HP (Agilent) 5347A 20 GHz

Microwave Counter / Power Meter

 

Equipment Notes:

This instrument combines a microwave frequency counter and RF Power Meter.  The counter will cover 10 Hz to 20 GHz frequency range.  The Power meter range is dependent on the sensor chosen.  The unit works with most, if not all of the 848x series sensors. 

  • Original Manual is included but not in the photos. 

  • 11730a Power Sensor Cable is included but no power sensors are included in auction.

  • Option 006 Microwave Level Limiter.

  • Option 011 HP-IB Interface.

We ran this instrument through its paces in our lab.  It performs flawlessly and is in excellent physical condition.

MRSP - With options was over $10,000.00

 

Product Specifications:

  • Frequency Range: 500 MHz to 20 GHz

  • Sensitivity 500 MHz - 12.4 GHz: -32 dBm (-35 dBm typical) 12.4 GHz - 20.0
    GHz: -27 dBm (-32 dBm typical)

  • Maximum Input: +7 dBm Damage Level: +25 dBm, peak SWR 500 MHz - 12.4 GHz: <2:1 typical 12.4 GHz - 20.0 GHz: <3:1 typical

  • Accuracy: ±1 LSD ±time base error x frequency

  • Resolution: 1 Hz or 10 kHz, selectable


Optional Increased Damage Level Opt 006 Protects Input 1 from damage by limiting high level signals. All specifications are the same except Input 1.

Damage Level 500 MHz to 6 GHz: +39 dBm (8 watts) 6 GHz to 18 GHz: +36 dBm (4 watts) Sensitivity reduced by 3 dBm, 500 MHz to 12.4 GHz 4 dBm, 12.4 GHz to 20.0 GHz

Input 2

  • Frequency Range: 10 Hz - 525 MHz

  • Sensitivity: 25 mV rms (15 mV rms typical)

  • Impedance: 1 Mohm nominal shunted by <70 pF (10 Hz to 80 MHz) or 50 Ù nomimnal (10 MHz to 525 MHz)

  • Damage Level: 50 Ù or 1 MÙ dc - 5 kHz: 250V (dc + ac peak) >5 KHz: 5.5V rms (+28 dBm) + 1.25 x 106 Vrms/FREQ

  • Accuracy: ±1 LSD ±[(1.4 x Trigger Error/Gate Time) ±Time Base Error] x frequency

  • Resolution: 1 Hz or 10 kHz, selectable


Automatic Amplitude Discrimination Automatically measures the largest of all signals present, provided that signal is>6 dB (typical) above any signal within 500 MHz; >20 dB (typical) above any signal within 500 MHz to 20 GHz.

  • Tracking Speed Resolution = 1 Hz, Speed = 1 MHz/sec Resolution = 10 kHz, Speed = 1 GHz/sec Acquisition Time

  • Resolution = 1 Hz, Time = <125 ms Resolution = 10 kHz, Time = <60 ms Maximum Deviation 20 MHz p-p, Automatic mode 60 MHz p-p, Manual mode (via HP-IB only)
    Maximum FM Rate: 10 MHz

  • AM Tolerance: Any modulation index provided the minimum signal level is not less than the sensitivity specification.

Power Meter

  • Frequency Range: 0 MHz to 20 GHz, sensor dependent Power Range: -70 dBm to +20 dBm (100 pW to 100 mW), sensor dependent

  • Dynamic Range: 50 dB in 10 dB steps Resolution: 0.01 dB in logarithmic mode, 0.1% of full scale in linear mode.

  • Auto Filter: The meter automatically selects the required number of averages for the selected range.

  • Accuracy Instrumentation: ±0.02 dB or ±5%

  • Zero Set (digital settability of zero): ±5% of full scale on most sensitive range. Decrease percentage by a factor of 10 for each higher range, ±1 display count.

 




Warranty:

This item is sold with a 3 Day Satisfaction Guarantee.  So bid with confidence.
As our many customers will attest, we will do our very best to resolve any customer problems. But our official policy is:

  • This item comes with a 3 day right of return policy.

  • All returns must be made within 3 days of receipt.

  • All warranties are void if the calibration / warranty seals are broken.

  • Equipment must be shipped correctly and returned with all accessories.

  • Customer is responsible for all shipping charges on returns.

  • Foreign Buyers please be aware: We offer no warranty or returns on items shipped outside the USA

Payment, Shipping & Bidding:

Buyer will pay $35.00 packing and shipping in the continental United States. Payments accepted are Paypal, cashiers checks and money orders only. No international buyers unless paypal verified.  Please feel free to contact us if you need other arrangements.

We will make every effort to ship within 24 hours of receipt of payment. We ship with FedEx & UPS only. We will be glad to ship with other carriers using the purchasers shipping account. Please contact us to make any special shipping arrangements. For shipping rate research, our shipping address is Boulder, CO USA ---- Zip Code is 80305.

Many of our auctions have a set packaging and shipping fee.  This set fee makes the transaction easier and allows the purchaser to send payment at once without having to wait for a shipping total.  This is our best guess on an unpackaged item.  Please consider the total with shipping when you are bidding.

Foreign buyers: Unless special provisions have been made, you are responsible for making your own shipping arrangements and all costs related to customs, duties & special packaging requirements. Please do not ask us to quote you international shipping rates. Use the address information above to research you own shipping rates. You can email sales@ascentconcepts (no spam) .com to get the packaging fee, package weight and size for your research. Items sold outside the USA are sold as is.

Bidders - with no feedback or less then 80% positive feedback must contact us through the ebay email system before placing a bid. We will reply through the same system, documenting that you have been approved to bid. If you do not follow these procedures, your bid will be cancelled.  All other bidders, bid with confidence.

 

About Us:

Ascent Concepts and Technologies is a Research & Development Lab. As a service to the companies and institutions we work with, we broker their excess equipment & act as application specialists on their new equipment needs. We are now offering quality used equipment to the public with the same level of professionalism and service.

Please feel free to email at thomasknox@ascentconcepts (no spam) .com or call Thomas @ 1-303-554-0307 with any Technical questions. Please feel free to email at waltwhite@ascentconcepts (no spam) .com or call Walt @ 1-720-276-8288 with any Shipping or Logistical questions. We make every effort to evaluate and guarantee our equipment. Although we do not provide NIST traceable calibration, we do have extensive in house calibration equipment and make every effort to test and verify performance on equipment we sell. However we do not warranty any items shipped outside the USA