HP/Agilent 5342A
CW Microwave Frequency Counter
(w/ OPT 006: Limiter Input Protection)
Included:
* HP 5342A Counter
* HP 5342A Operation and Service Manual
Characteristics:
The HP 5342A Microwave Counter provide Automatic Frequency Measurements up to
18 to 26.5 GHz in highly portable packages. The powerful and versatile
microprocessor controlled keyboards can accomplish offset tasks as a standard
feature as well as providing user interactive diagnostic information. The
eleven-digit display is sectionalized for easy readout to one hertz resolution.
This unit utilizes the Harmonic Heterodyne down conversion technique which
combines the best performance features of the Heterodyne Converter and Transfer
Oscillator Techniques. Now Wide FM Tolerance is achievable along with high input
sensitivity and automatic amplitude discrimination. This allows the counter to
automatically measure the largest signal present within the counters' spectrum
while ignoring all others.
Specifications:
Input 1:
- Frequency Range: 500 MHz to 18 GHz
- Sensitivity:
- 500 MHz to 12.4 GHz: -25 dBm
- 12.4 GHz to 18 GHz: -20 dBm
- Maximum Input: +5 dBm
- Connector: Precision Type N female
Input 2:
- Frequency Range: 10 Hz to 520 MHz Direct Count
- Sensitivity:
- 50 ohms: 10 Hz to 520 MHz, 25 mV rms
- 1 Mohm: 10 Hz to 25 MHz, 25 mV rms
- Maximum Input: 50 ohms 3.5V rms (+24 dBm) or 5V dc fused protected;
1 Mohm 200V dc +5.0V rms
- Coupling: AC
- Connector: Type BNC (female)
- Impedance: Selectable, 1 Mohm, <50 pF or 50 ohm nominal
This unit is tested and is fully operational.
It was built
back in the golden era of HP and is "Beautifully Constructed!"
The main cause of microwave counter failure is front-end
overload.
This unit includes the very desirable option 006,
which is a front-end
limiter that will protect the input from damage from CW signals up to +39dBm. (8
watts)
|