Elgar 1001 SX
w/Series 9012
Plug In Oscillator
This auction includes one Elgar 1001SX with a Series 9012
Plug in controller. If the time has come for an AC power source a bit
more sophisticated then your old Variac, this Elgar system is just what you
need. The system was just pulled from service in our lab and performs
flawlessly. Included in this auction are
the manuals for both the 1001SX and the 9012. We
have several additional 1001SX and SL slave units. We will be glad to
list for you if you are interested.
Elgar 1001SX
The Elgar
1001SX AC linear power source is an extremely versatile design that
can meet all your needs. It is fully capable of driving complexed
loads such as non-linear, capacitive input filter rectifier loads. It also
meets all the electrical power requirements for testing modern switch mode
DC power supplies.
Increased peak
power capacity and a reduced physical size make the 1001SX unit ideal for
bench top testing as well as for automated DC power supply test systems.
9012 Plug In
The Elgar 9012
is ready to plug in to any of our full line of AC linear power sources. They
are programmable via the IEEE-488 GPIB bus, or locally from the front panel
keypad.
Whether you
need a variable voltage, variable frequency, current limited supply for test
and repair, foreign power requirements, automated test equipment (ATE),
aircraft ground support, production lines or laboratories the series 9012
provide reliable programming that is easy to use. Elgar programmers are used
in aerospace, military, commercial and telecommunications electronic
applications around the world.
Output
-
Voltage Range: 0-130 / 0-260 VAC (varies per model). Specific output
range is selected by jumper change on rear panel. Consult Elgar for other
voltage ranges.
-
Power Range: 0 to 1000 Watts
-
Rated Power Voltage Range: Full rated VA from 55-65 VAC, 110-130 VAC,
or 220-260 VAC over a ±10% input and rated PF range. Continuous duty at
150% of rated capacity at 55°C*
-
Load
Power Factor: Unity to ±0.7 PF to rated VA with an output voltage
adjustment range of 80-100% of full scale*
-
Frequency Range: 45 Hz to 1kHz
-
Total Harmonic Distortion:
0.5% from 45 Hz to 1 kHz with linear load
1.0% from 45 Hz to 75 Hz with pulsed load
4.0% from 75 Hz to 450 Hz with pulsed load
-
Load
Regulation: ±1% from 45 Hz to 450 Hz with pulsed load or from 45 Hz to
1 kHz with linear load
-
Line
Regulation: ±0.25% at rated load for a ±10% input change at full scale
output voltage
-
Response Time: <2 ms
-
AC
Noise Level: 70 dB below full output voltage with input grounded
Input
-
Voltage: 115/208/230 VAC, ±10% (208 VAC not available on 501 SX.) User
selectable (See model
description)
-
Frequency: 47 to 63 Hz (400 Hz option, special order)
-
Efficiency: Up to 45%
General
-
Operating Temperature Range: 0° to +55°C
-
Operating Humidity Range: Up to 95% non-condensing
-
Metering: 0 to 300 VAC output voltmeter, ±3% accuracy
-
Controls: Input power switch/circuit breaker and pilot light. Full
range, 10-turn output voltage control potentiometer
|
9012A/AE
|
FREQUENCY
Range
|
Programmable
45-99.99 Hz
45-999.9 Hz
45-5000 Hz
|
Resolution |
0.01/0.1/1.0 Hz
|
Accuracy |
0.001% of
Set Value
|
External Frequency/
Phase
Synchronization
|
No
|
VOLTAGE
Mode |
Programmable
Simultaneously
|
Range |
0-135 VAC
0-270 VAC
|
Resolution |
0.1 VAC
|
Programming
Accuracy |
±0.2% of Full
Scale
|
Load Regulation |
±0.015%; No
Load to Full Load
|
Line Regulation |
±0.015%; for a
10% Line Change
|
CURRENT LIMIT
(Requires test option)
|
Programmable
Simultaneously
(All Phases)
|
Range |
5%-100%
|
PHASE ANGLE
PROGRAMMING |
Single ø, Two ø
Fixed 90°
3ø , Fixed 120°
|
Range |
N/A
|
Resolution |
N/A
|
Accuracy |
±1°; 45-2 kHz
Add 1°
Per kHz
above 2 kHz
|
Fault Shutdown |
Over/Under
Voltage
Overload
Over Current*
|
Programmable
Amplitude
Execution |
Random/Zero
Crossing Peak
|
Line Cycle Drop-Out |
Programmable
1-9 Cycles
|
Flat Top Distortion |
N/A
|
MEASUREMENT
READBACK
FREQUENCY
Range
|
45 Hz-5 kHz
|
Resolution |
2 Hz
|
Accuracy |
0.12%
±0.8% Reading
|
TRUE RMS
VOLTAGE
Range |
0-300 VAC
|
Resolution |
0.1 VRMS
|
Accuracy |
0.1% FS
±0.1% Reading
|
CURRENT
Range** |
0-5A, 10A, 20A,
40 ARMS
|
Resolution |
0.01 ARMS
|
Accuracy |
1% FS
±1% Reading
|
POWER
Range** |
0 - 1000 Watts
|
Resolution |
1W
|
Accuracy |
1% FS
±1% Reading
|
PHASE ANGLE
Range |
N/A
|
Resolution |
N/A
|
|
Shipping Policy
Buyer will pay $40.00 packing plus actual shipping in the continental United States. We
will make every effort to ship within 24 hours of receipt of payment. We
ship with FedEx only. We
will be glad to ship with other carriers using the purchasers shipping account. Please contact
us to make any special shipping arrangements. For shipping rate research,
our shipping address is Boulder, CO USA ---- Zip Code is 80305.
Foreign buyers:
Unless special provisions have
been made, you are responsible for making your own shipping arrangements and all
costs related to customs, duties & special packaging requirements.
Please do not ask us to quote you international shipping rates. Use the
address information above to research you own shipping rates. You can
email waltwhite@ascentconcepts.com